MEMECO has associated its name with some of the biggest brands in the firefighting solutions and fire engineering fields such as Pyronics, Kidde, Tyco, L.P.G and many others. MEMECO also provides complete firefighting solutions properly designed, supply, installed and maintained firefighting systems CO2 & FM200 & Novec™ 1230 clean & Fire Pumps
Systems successful at reducing fire casualties and property damage. We provide a wide variety of firefighting systems which depends on each customer and applications we are committed to provide you with quality service according to international standard
MEMECO offers a unique approach to fire protection that suits every special hazard application. We offer an integrated total system solution that starts with early fire detection and ends with quick fire suppression. Our detection systems are connected to our suppression control panels and are on-guard 24 hours a day.
The CO2 Fire Suppression System is an engineered system available in three application configurations: total flooding (for unoccupied areas), local application or hand-hose line. Gaseous carbon dioxide rapidly suppresses fire by a combination of cooling and oxygen displacement. Discharge duration and agent flow rates are customized for the individual application.
The versatile FM-200™ (HFC-227ea) and 3M™ Novec™ 1230 clean agent fire suppression systems that equally provide a total flood fire protection solution to protect valuable assets in occupied areas.
The packaged pump sets includes a wide variety of fire pump units start from 50 gpm size up to 1500 gpm, with pressure range from 6 bar up to 12 bar.
Fire Pump Unit Controller is the Pump Package brain that designed to Control & Monitor the operation of the Main, Standby, and Jockey pumps Drivers, and makes up pumps for both Manual & Automatic modes, as well as turns pumps drivers ON/OFF under specific conditions.
The Fire Pump Package Controller detects signals through set of built in switches that reflect the system Pressure & Flow status enabling fire pump package drivers(Electrical /Diesel /Jockey) to operate in case of pressure in the system is lower than set point, as well as operating the Stand by driver due to power failure and/or substantial drop in pressure.
A sprinkler is a nozzle attached to network of pipes, and installed just below the ceiling of a room. Every sprinkler has a small glass bulb with a liquid in it. This bulb normally blocks the flow of water. In a fire, the liquid in the bulb will become hot. It will then expand, and shatter the glass bulb, removing the obstacle and causing water to spray from the sprinkler. The main difference between a hydrant and a sprinkler is that a sprinkler will come on automatically in a fire.